RoboGait Studio: Análisis y Sincronización Multisensor de Marcha

Autores/as

  • Xiaofeng Han Centre for Automation and Robotics (CAR UPM-CSIC), Escuela Técnica Superior de Ingeniería y Diseño Industrial (ETSIDI), Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, Spain. https://orcid.org/0009-0003-8400-8383
  • Diego Guffanti Grupo de Investigación en Sistemas Embebidos y Robótica (GISER), Facultad de Ciencias de la Ingeniería e Industrias, Universidad UTE, Quito 170527, Ecuador https://orcid.org/0000-0002-1244-291X
  • Alberto Brunete Centre for Automation and Robotics (CAR UPM-CSIC), Escuela Técnica Superior de Ingeniería y Diseño Industrial (ETSIDI), Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, Spain https://orcid.org/0000-0001-9873-232X
  • Miguel Hernando Centre for Automation and Robotics (CAR UPM-CSIC), Escuela Técnica Superior de Ingeniería y Diseño Industrial (ETSIDI), Universidad Politécnica de Madrid, Madrid, Spain https://orcid.org/0000-0001-9997-0266
  • David Álvarez Centre for Automation and Robotics (CAR UPM-CSIC), Escuela Técnica Superior de Ingeniería y Diseño Industrial (ETSIDI), Universidad Politécnica de Madrid, Madrid, Spain https://orcid.org/0000-0003-2056-640X

DOI:

https://doi.org/10.17979/ja-cea.2026.47.13732

Palabras clave:

Robots móviles, Visión por computador, Sistemas biomédicos, Análisis del movimiento, Fusión de sensores, Procesamiento de datos

Resumen

RoboGait Studio es una plataforma software diseñada para el análisis sincronizado de la marcha mediante múltiples sensores y la comparación entre sistemas. La herramienta integra la gestión de participantes y ensayos, visualización de señales, sincronización temporal, normalización de ciclos de marcha y análisis comparativo dentro de un flujo de trabajo unificado. La alineación temporal se realiza utilizando trayectorias de distancia entre tobillos obtenidas de registros adquiridos de forma independiente, evitando la necesidad de sincronización a nivel hardware. El marco fue evaluado utilizando datos pareados procedentes de un sistema RGB-D montado sobre un robot móvil y un sistema de captura de movimiento VICON. Los resultados demostraron una sincronización precisa y una buena concordancia entre sistemas para parámetros espacio-temporales y cinemáticos representativos. La plataforma proporciona una base flexible para futuras aplicaciones de análisis de la marcha en línea y en tiempo real.

Referencias

Balta, H., Velipasalar, S., Cavusoglu, M. C., 2024. RGB-D Sensor-Based Gait Analysis for Neurological Rehabilitation and Clinical Assessment. IEEE Access, 12, 25411–25429. DOI: 10.1109/ACCESS.2024.3361287

Barzyk, M., Kwolek, B., Michalczuk, A., 2024. Robot-Assisted Gait Monitoring Using RGB-D Sensing Technologies in Clinical Environments. Robotics and Autonomous Systems, 176, 104698. DOI: 10.1016/j.robot.2024.104698

Clark, R. A., Mentiplay, B. F., Pua, Y. H., Bower, K. J., 2021. Reliability and Validity of Technology-Based Gait Assessment in Clinical Applications. Sensors, 21(7), 2308. DOI: 10.3390/s21072308

Fritsch, F. N., Carlson, R. E., 1980. Monotone Piecewise Cubic Interpolation. SIAM Journal on Numerical Analysis, 17(2), 238–246. DOI: 10.1137/0717021

Han, X., Guffanti, D., Brunete, A., 2025. A Comprehensive Review of Vision-Based Sensor Systems for Human Gait Analysis. Sensors, 25(2), 498. DOI: 10.3390/s25020498

Lagomarsino, M., Rossi, S., Bianchi, M., 2024. Markerless Motion Capture Technologies for Biomechanical Gait Assessment: A Systematic Review. Journal of Biomechanics, 172, 112245. DOI: 10.1016/j.jbiomech.2024.112245

Mentiplay, B. F., Perraton, L. G., Bower, K. J., et al., 2021. Gait Assessment Using Wearable and Vision-Based Technologies in Neurological Populations. Gait & Posture, 84, 277–293. DOI: 10.1016/j.gaitpost.2020.12.017

Muro-de-la Herran, A., Garcia-Zapirain, B., Mendez-Zorrilla, A., 2014. Gait Analysis Methods: An Overview of Wearable and Non-Wearable Systems. In: Highlights of Practical Applications of Heterogeneous Multi-Agent Systems. Springer, pp. 407–414. DOI: 10.1007/978-3-319-07767-340

Smirnova, D., Sazonov, E., Huo, Z., 2022. Evaluation of Kinect-Based Gait Analysis Systems Compared with Optical Motion Capture. Sensors, 22(9), 3275. DOI: 10.3390/s22093275

VICON Motion Systems Ltd., 2024. Vicon Nexus Documentation. Available online: https://www.vicon.com/

Vun, C. H., Lee, J. Y., Lim, W. H., et al., 2024. Recent Advances in Markerless Gait Analysis Technologies for Clinical and Rehabilitation Applications. Biomedical Signal Processing and Control, 89, 105741. DOI: 10.1016/j.bspc.2023.105741

Winter, D. A., 2009. Biomechanics and Motor Control of Human Movement (4th Edition). John Wiley & Sons.

Yeung, L. F., Yang, Z., Cheng, K. C. C., Du, D., Tong, R. K. Y., 2021. Evaluation of the Microsoft Azure Kinect for Clinical Gait Analysis. PLoS ONE, 16(2), e0246073. DOI: 10.1371/journal.pone.0246073

Descargas